Main
Range of product PowerLogic
product name PowerTag R200
product or component type Energy sensor
Poles 3P
3P + N
Maximum current [Imax] 200 A
[Ib] basic current 30 A
starting current 120 mA
saturation current 400 A
product specific application Energy management
Overload alarm
Power factor
Load monitoring
Circuit monitoring
Concentrator compatibility Acti9 PowerTag Link C
Acti9 PowerTag Link
Acti9 PowerTag Link HD
Harmony Hub
EcoStruxure Panel Server Universal
EcoStruxure Panel Server Advanced
PrismaSet Active
range compatibility MasterPact MTZ switch disconnector
MasterPact NW
MasterPact NT
ComPact NS
range compatibility Acti9
TeSys
type of measurement Active and reactive energy
Apparent energy
Active and reactive power
Apparent power
Current
Voltage
Power factor
Internal temperature
Frequency
accuracy class Class 1 active energy conforming to IEC 61557-12
Class 2 reactive energy conforming to IEC 61557-12
Class 2 apparent energy conforming to IEC 61557-12
Class 1 active power conforming to IEC 61557-12
Class 2 reactive power conforming to IEC 61557-12
Class 2 apparent power conforming to IEC 61557-12
Class 1 current conforming to IEC 61557-12
Class 0.5 voltage conforming to IEC 61557-12
Class 1 power factor conforming to IEC 61557-12
Class 0.5 frequency conforming to IEC 61557-12
metering type Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at total per phase
Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at partial per phase
Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at 3-phase total
Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at 3-phase partial
Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at total per phase
Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at partial per phase
Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at 3-phase total
Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at 3-phase partial
Apparent energy E -apA- 0...281 x 10exp(9) kVAh at total per phase
Apparent energy E -apA- 0...281 x 10exp(9) kVAh at partial per phase
Apparent energy E -apA- 0...281 x 10exp(9) kVAh at 3-phase total
Apparent energy E -apA- 0...281 x 10exp(9) kVAh at 3-phase partial
Active power P, P1, P2, P3
Reactive power Q, Q1, Q2, Q3
Apparent power S, S1, S2, S3
Current I1, I2, I3
Calculated neutral current
Voltage U12, U23, U31
Voltage V1N, V2N, V3N
Frequency 45...65 Hz
Power factor at per phase
Power factor at total
mounting location Top or bottom
mounting support Busbar
Cables
product destination Switchboard
Event management Voltage loss with measured current at voltage loss
transmission support medium Radio frequency 2.4…2.4835 GHz conforming to IEEE 802.15.4
emission power 10 mW
Complementary
mounting mode Clip-on (DIN rail)
Electrical connection (voltage sensing & power supply) Removable spring terminal block
cable cross section 1 rigid cable 0.2…1.5 mm² without cable end
1 stranded cable 0.2…2.5 mm² without cable end
1 stranded cable 0.25…1.5 mm² with cable end
wire stripping length 11 mm
cable length 1 m for sensor
current sensor diameter Closed: 100 mm
supply voltage 100...277 V AC, +/- 20 %, phase to neutral
173...480 V AC, +/- 20 %, phase to phase
network frequency 50 Hz
60 Hz
Maximum power consumption 3 VA
standards IEC 61557-12
IEC 61010-1
ETSI EN 301 487-1
IEC 61010-2-030
IEC 61326-1
ETSI EN 300 328
Number of 9mm pitches on Din rail 2
height Base unit: 105 mm
width Base unit: 18 mm
depth Base unit: 67.5 mm
colour White (RAL 9003)
Environment
maximum conductor temperature 105 °C
quality labels CE
directives 2014/53/EU - radio equipment directive
operating altitude 0...2000 m
ambient air temperature for operation -25…70 °C
ambient air temperature for storage -40…85 °C
overvoltage category IV conforming to IEC 61010-1
measurement category Category IV conforming to IEC 61010-2-030
IP degree of protection IP20 conforming to IEC 60529
IK degree of protection IK05
pollution degree 3
relative humidity 0…95 % at 55 °C conforming to IEC 60721-3-3
vibration resistance 3M4 conforming to IEC 60721-3-3
electromagnetic compatibility Industrial electromagnetic environment conforming to IEC 61326-1
Radiated EMC conforming to ETSI EN 301 489-17
Electromagnetic emission conforming to IEC 62311
environmental characteristics Indoor use
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 565.0 g
Package 1 Height 8.0 cm
Package 1 width 17.5 cm
Package 1 Length 20.0 cm
Unit Type of Package 2 S03
Number of Units in Package 2 7
Package 2 Weight 4.432 kg
Package 2 Height 30.0 cm
Package 2 width 30.0 cm
Package 2 Length 40.0 cm

DOWNLOADS

Payment & Security

American Express Apple Pay Google Pay Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed