Schneider Electric 240v AC to 24v DC 0.6A single pole power supply.

Frequently bought with C-Bus Automation Controller's 5500AC2 and 5500NAC2.

Main

Range of product Modicon Power Supply
Product or component type Power supply
Power supply type Regulated switch mode
Variant option Modular
Enclosure material Plastic
Nominal input voltage 100...240 V AC single phase
100...240 V AC 2 phases
Rated power in W 15 W
output voltage 24 V DC
Power supply output current 0.625 A

 

Complementary

Input voltage limits 90...264 V AC
Nominal network frequency 50…60 Hz
Network system compatibility TN
TT
IT
maximum leakage current 0.25 mA 240 V AC
input protection type Integrated fuse (not interchangeable) 3.15 A
External protection (recommended) 20 A Curve B
External protection (recommended) 20 A Curve C
External protection (recommended) 2 A Curve B
External protection (recommended) 2 A Curve C
inrush current 15 A at 115 V
30 A at 230 V
power factor 0.51 at 115 V AC
0.40 at 230 V AC
efficiency 81 % at 115 V AC
81 % at 230 V AC
Power dissipation in W 3.5 W
current consumption < 0.4 A 115 V AC
< 0.25 A 230 V AC
Turn-on time < 2 s
holding time > 10 ms 115 V AC
> 60 ms 230 V AC
Startup with capacitive loads 3000 µF
Residual ripple < 100 mV
Expected capacitor life time 10 year(s)
meantime between failure [MTBF] 3000000 h at 25 °C, full load
1000000 h at 55 °C, 80 % load
output protection type Against overload and short-circuits, protection technology: automatic reset
Against over temperature, protection technology: manual reset
Against overvoltage, protection technology: manual reset
connections - terminals Screw connection: 0.5...1.5 mm², (AWG 20...AWG 16) without wire end ferrule for input/output
Screw connection: 0.5...1 mm², (AWG 20...AWG 18) with wire end ferrule for input/output
line and load regulation < 0.5 % network in line
< 1 % network 0 to 100 % load
status LED 1 LED (green) output voltage
Depth 55.6 mm
Height 91 mm
Width 18 mm
Net weight 0.101 kg
Output coupling Serial
mounting support Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Double-profile DIN rail
panel mounting
supply SELV conforming to EN/IEC 60950-1
SELV conforming to EN/IEC 60204-1
SELV conforming to IEC 60364-4-41
dielectric strength 3000 V AC input/output

 

Environment

Standards EN 62368-1
EN/IEC 61010-1
EN 61010-2-201
EN/IEC 61204-3
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
EN 61000-3-2
EN 61000-3-3
UL 62368-1
UL 61010-1
UL 61010-2-201
CSA C22.2 No 62368-1
CSA C22.2 No 61010-1
CSA C22.2 No 61010-2-201
EN/IEC 62368-1
product certifications CE
CUL listed
CUL recognized
RCM
CB Scheme
EAC
KC
NEC: class 2
operating altitude < 2000 m overvoltage category III
2000 m...5000 m overvoltage category II
shock resistance 100 m/s² for 11 ms
IP degree of protection IP20
Ambient air temperature for operation -25…55 °C without current derating mounting position A < 2000 m
55…70 °C with current derating of 2.67 % per °C mounting position A < 2000 m
electrical shock protection class Class II without PE connection
Pollution degree 2
vibration resistance 3 mm (f= 2…9 Hz) conforming to IEC 60721-3-3
10 m/s² (f= 9…200 Hz) conforming to IEC 60721-3-3
Electromagnetic immunity Immunity to electrostatic discharge - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Immunity to electrostatic discharge - test level: 9 kV (air discharge) conforming to EN/IEC 61000-4-2
Electromagnetic field immunity test - test level: 10 V/m (80 MHz...2 GHz) conforming to EN/IEC 61000-4-3
Electromagnetic field immunity test - test level: 5 V/m (2...2.7 GHz) conforming to EN/IEC 61000-4-3
Electromagnetic field immunity test - test level: 3 V/m (2.7...6 GHz) conforming to EN/IEC 61000-4-3
Immunity to fast transients - test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4
Surge immunity test - test level: 3 kV (between power supply and earth) conforming to EN/IEC 61000-4-5
Surge immunity test - test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5
Immunity to conducted disturbances - test level: 10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6
Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8
Immunity to voltage dips - test level: 100 % (1 cycle) conforming to EN/IEC 61000-4-11
Immunity to voltage dips - test level: 60 % (10 cycles) conforming to EN/IEC 61000-4-11
Immunity to voltage dips - test level: 30 % (25 cycles) conforming to EN/IEC 61000-4-11
Disturbing field emission conforming to EN 55016-2-3
Limits for harmonic current emissions conforming to EN 61000-3-2
Conducted disturbance emission conforming to EN 55016-1-2
Conducted disturbance emission conforming to EN 55016-2-1
electromagnetic emission Conducted emissions conforming to EN 61000-6-3
Radiated emissions conforming to EN 61000-6-4

 

DOWNLOADS

You may also like

Recently viewed

Delivery

We deliver lighting products across Australia. Delivery charges are calculated at checkout. Some bulky products and remote-area deliveries may require a revised freight quotation. We will contact you before dispatch if any additional freight charges apply.

Available products are generally dispatched within 1–3 business days. Delivery normally takes an additional 2–10 business days, depending on the delivery location, supplier location and size of the products. We will contact you if an item has a longer lead time.

We use a range of national freight carriers and local couriers. The carrier is selected based on the size of the order and the delivery location.

Need help choosing the correct product?

Please contact us before returning any product. Returns are assessed in accordance with our Terms and Conditions and may be subject to supplier approval, return freight and restocking charges. Products must not be installed, used or damaged unless the product is being returned due to a fault.

Other

Our lighting team can help confirm specifications, compatibility and product availability before you order. Call us on (02) 9517 2701 or email sales@ecosmartlighting.com.au.

Call us

(02) 9517 2701

Email us

sales@ecosmartlighting.com.au