Description
Schneider Electric 240v AC to 24v DC 0.6A single pole power supply.
Frequently bought with C-Bus Automation Controller's 5500AC2 and 5500NAC2.
Main
| Range of product | Modicon Power Supply |
|---|---|
| Product or component type | Power supply |
| Power supply type | Regulated switch mode |
| Variant option | Modular |
| Enclosure material | Plastic |
| Nominal input voltage | 100...240 V AC single phase 100...240 V AC 2 phases |
| Rated power in W | 15 W |
| output voltage | 24 V DC |
| Power supply output current | 0.625 A |
Complementary
| Input voltage limits | 90...264 V AC |
|---|---|
| Nominal network frequency | 50…60 Hz |
| Network system compatibility | TN TT IT |
| maximum leakage current | 0.25 mA 240 V AC |
| input protection type | Integrated fuse (not interchangeable) 3.15 A External protection (recommended) 20 A Curve B External protection (recommended) 20 A Curve C External protection (recommended) 2 A Curve B External protection (recommended) 2 A Curve C |
| inrush current | 15 A at 115 V 30 A at 230 V |
| power factor | 0.51 at 115 V AC 0.40 at 230 V AC |
| efficiency | 81 % at 115 V AC 81 % at 230 V AC |
| Power dissipation in W | 3.5 W |
| current consumption | < 0.4 A 115 V AC < 0.25 A 230 V AC |
| Turn-on time | < 2 s |
| holding time | > 10 ms 115 V AC > 60 ms 230 V AC |
| Startup with capacitive loads | 3000 µF |
| Residual ripple | < 100 mV |
| Expected capacitor life time | 10 year(s) |
| meantime between failure [MTBF] | 3000000 h at 25 °C, full load 1000000 h at 55 °C, 80 % load |
| output protection type | Against overload and short-circuits, protection technology: automatic reset Against over temperature, protection technology: manual reset Against overvoltage, protection technology: manual reset |
| connections - terminals | Screw connection: 0.5...1.5 mm², (AWG 20...AWG 16) without wire end ferrule for input/output Screw connection: 0.5...1 mm², (AWG 20...AWG 18) with wire end ferrule for input/output |
| line and load regulation | < 0.5 % network in line < 1 % network 0 to 100 % load |
| status LED | 1 LED (green) output voltage |
| Depth | 55.6 mm |
| Height | 91 mm |
| Width | 18 mm |
| Net weight | 0.101 kg |
| Output coupling | Serial |
| mounting support | Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 Double-profile DIN rail panel mounting |
| supply | SELV conforming to EN/IEC 60950-1 SELV conforming to EN/IEC 60204-1 SELV conforming to IEC 60364-4-41 |
| dielectric strength | 3000 V AC input/output |
Environment
| Standards | EN 62368-1 EN/IEC 61010-1 EN 61010-2-201 EN/IEC 61204-3 EN 61000-6-1 EN 61000-6-2 EN 61000-6-3 EN 61000-6-4 EN 61000-3-2 EN 61000-3-3 UL 62368-1 UL 61010-1 UL 61010-2-201 CSA C22.2 No 62368-1 CSA C22.2 No 61010-1 CSA C22.2 No 61010-2-201 EN/IEC 62368-1 |
|---|---|
| product certifications | CE CUL listed CUL recognized RCM CB Scheme EAC KC NEC: class 2 |
| operating altitude | < 2000 m overvoltage category III 2000 m...5000 m overvoltage category II |
| shock resistance | 100 m/s² for 11 ms |
| IP degree of protection | IP20 |
| Ambient air temperature for operation | -25…55 °C without current derating mounting position A < 2000 m 55…70 °C with current derating of 2.67 % per °C mounting position A < 2000 m |
| electrical shock protection class | Class II without PE connection |
| Pollution degree | 2 |
| vibration resistance | 3 mm (f= 2…9 Hz) conforming to IEC 60721-3-3 10 m/s² (f= 9…200 Hz) conforming to IEC 60721-3-3 |
| Electromagnetic immunity | Immunity to electrostatic discharge - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2 Immunity to electrostatic discharge - test level: 9 kV (air discharge) conforming to EN/IEC 61000-4-2 Electromagnetic field immunity test - test level: 10 V/m (80 MHz...2 GHz) conforming to EN/IEC 61000-4-3 Electromagnetic field immunity test - test level: 5 V/m (2...2.7 GHz) conforming to EN/IEC 61000-4-3 Electromagnetic field immunity test - test level: 3 V/m (2.7...6 GHz) conforming to EN/IEC 61000-4-3 Immunity to fast transients - test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4 Surge immunity test - test level: 3 kV (between power supply and earth) conforming to EN/IEC 61000-4-5 Surge immunity test - test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5 Immunity to conducted disturbances - test level: 10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6 Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8 Immunity to voltage dips - test level: 100 % (1 cycle) conforming to EN/IEC 61000-4-11 Immunity to voltage dips - test level: 60 % (10 cycles) conforming to EN/IEC 61000-4-11 Immunity to voltage dips - test level: 30 % (25 cycles) conforming to EN/IEC 61000-4-11 Disturbing field emission conforming to EN 55016-2-3 Limits for harmonic current emissions conforming to EN 61000-3-2 Conducted disturbance emission conforming to EN 55016-1-2 Conducted disturbance emission conforming to EN 55016-2-1 |
| electromagnetic emission | Conducted emissions conforming to EN 61000-6-3 Radiated emissions conforming to EN 61000-6-4 |
DOWNLOADS
You may also like
Recently viewed
Delivery
We deliver lighting products across Australia. Delivery charges are calculated at checkout. Some bulky products and remote-area deliveries may require a revised freight quotation. We will contact you before dispatch if any additional freight charges apply.
Available products are generally dispatched within 1–3 business days. Delivery normally takes an additional 2–10 business days, depending on the delivery location, supplier location and size of the products. We will contact you if an item has a longer lead time.
We use a range of national freight carriers and local couriers. The carrier is selected based on the size of the order and the delivery location.
Need help choosing the correct product?
Please contact us before returning any product. Returns are assessed in accordance with our Terms and Conditions and may be subject to supplier approval, return freight and restocking charges. Products must not be installed, used or damaged unless the product is being returned due to a fault.
Other
Our lighting team can help confirm specifications, compatibility and product availability before you order. Call us on (02) 9517 2701 or email sales@ecosmartlighting.com.au.
Ask a Lighting Specialist
Need help confirming a product specification, model number or compatibility? Contact our lighting team before placing your order.